Dec 29, 2015

Can people step on the modules?


Can people step on the modules?


 Can people step on the modules? Although we have seen a lot of module damage in the field (On-siteEL is starting a quality revolution), but many people still doubt it. Frequently asked question is that modules can pass 5400Pa mechanical load test, which is 890 kg uniformly distributes on standard module (1.65m x 1m), why workers with weight less than 100 kg can not step on the module?

Dec 20, 2015

The Impact of Typhoon on PV Systems (2/2)- Module Strength

 The Impact of Typhoon on PV Systems (2/2)- Module Strength

3. Module Strength
  Module strength mainly depends on the glass, frame, cell breakability and the interaction of all these factors.

The Impact of Typhoon on PV Systems (1/2)

The Impact of Typhoon on PV Systems (1/2)

  Most PV modules are certified with mechanical load test, which means they are supposed to stand the high pressure brought by storms. But why are there still damages due to storms?

Nov 8, 2015

On-site EL is starting a quality revolution


On-site EL is starting a quality revolution


EL inspection is commonly used in module production lines, most buyers request  100% module EL inspection before delivery. Unfortunately the same quality request is not applied to the PV plants.
The above photo shows an EL image of a PV array, serious cell breakage is found in the middle of the modules. This kind of breakage frequently happens during installation or maintenance, but only few really check it on the PV array. EPCs request a very high quality standard for modules, but many of them do not apply the same request level to their installations. We have seen many installers and panel cleaning workers walking on the modules, and some owners even invite guests to take photos standing on the modules.